Dell PowerEdge R415 User Manual
Page 32

32
About Your System
E1716 Chipset IERR
Bus ## Dev ##
Function ##.
Review & clear
SEL.
The system BIOS reported
a chipset internal error
that resides in bus ##,
device ##, function ##.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and
restart the system.
If the problem persists,
E1717 CPU # internal
error. Review
& clear SEL.
The system BIOS
determined that the
specified processor has
had an internal error.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and
restart the system.
If the problem persists,
E171F PCIe fatal
error on Bus
## Device ##
Function ##
The system BIOS has
reported a PCIe fatal
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
PCIe fatal
error on Slot
#. Review &
clear SEL.
The system BIOS reported
a PCIe fatal error on a
component that resides in
the specified slot.
Remove and reseat the
expansion-card riser. See
page 99. If the problem
persists, the riser card or
system board is faulty.
Table 1-2. LCD Status Messages (Optional)
(continued)
Code
Text
Causes
Corrective Actions
R415HOM.book Page 32 Friday, September 24, 2010 9:37 AM