Dell PowerEdge R415 User Manual

Page 32

Advertising
background image

32

About Your System

E1716 Chipset IERR

Bus ## Dev ##
Function ##.
Review & clear
SEL.

The system BIOS reported

a chipset internal error

that resides in bus ##,

device ##, function ##.

Check the SEL for more

information, and then

clear the SEL. Remove

AC power to the system

for 10 seconds, and

restart the system.
If the problem persists,

see "Getting Help" on

page 181.

E1717 CPU # internal

error. Review
& clear SEL.

The system BIOS

determined that the

specified processor has

had an internal error.

Check the SEL for more

information, and then

clear the SEL. Remove

AC power to the system

for 10 seconds, and

restart the system.
If the problem persists,

see "Getting Help" on

page 181.

E171F PCIe fatal

error on Bus
## Device ##
Function ##

The system BIOS has

reported a PCIe fatal

error on a component

that resides in PCI

configuration space at

bus ##, device ##,

function ##.

Remove and reseat the

PCIe expansion cards.

If the problem persists,

see "Troubleshooting

Expansion Cards" on

page 165.

PCIe fatal
error on Slot
#. Review &
clear SEL.

The system BIOS reported

a PCIe fatal error on a

component that resides in

the specified slot.

Remove and reseat the

expansion-card riser. See

"Expansion Card and

Expansion-Card Riser" on

page 99. If the problem

persists, the riser card or

system board is faulty.

See "Getting Help" on

page 181.

Table 1-2. LCD Status Messages (Optional)

(continued)

Code

Text

Causes

Corrective Actions

R415HOM.book Page 32 Friday, September 24, 2010 9:37 AM

Advertising