E1410 System Fatal

Error
detected.

A fatal system error

detected.

Check LCD for

additional scrolling

messages. Remove AC

power to the system for

10 seconds and restart the

system. If the problem

persists, see "Getting

Help" on page 181.

E1414 CPU # temp

exceeding
range. Check
CPU heatsink.

Specified processor is out

of acceptable temperature

range.

Ensure that the processor

heat sinks are properly

installed. See

"Troubleshooting the

Processors" on page 166

and "Troubleshooting

System Cooling

Problems" on page 156.

E1418 CPU # not

detected.
Check CPU is
seated
properly.

Specified processor is

missing or bad, and the

system is in an

unsupported

configuration.

Ensure that the specified

microprocessor is

properly installed. See

"Troubleshooting the

Processors" on page 166.

E141C Unsupported

CPU
configuration.
Check CPU or
BIOS revision.

Processors are in an

unsupported

configuration.

Ensure that your

processors match and

conform to the type

described in the processor

technical specifications

outlined in your system’s

Getting Started Guide.

E141F CPU # protocol

error. Power
cycle AC.

The system BIOS

has reported a processor

protocol error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 181.