E1810 Hard drive ##

fault. Review
& clear SEL.

The specified hard-drive

has experienced a fault.

See "Troubleshooting a

Hard Drive" on page 163.

E1812 Hard drive ##

removed. Check
drive.

The specified hard-

drive has been removed

from the system.

Information only.

E1920 iDRAC6 Upgrade

Failed

The iDRAC6 Express card

is not installed properly or

the card is bad.

Reseat the iDRAC6

Express Card. See

Installing an iDRAC6

Express Card. If the

problem persists, see

"Getting Help" on

page 181.

E1A11 PCI Riser

hardware &
configuration
mismatch.
Reconfigure.

PCIe risers are not

configured correctly.

Some invalid

configurations prevent the

system from powering on.

Reinstall the expansion-

card riser. See "Expansion

Card and Expansion-

Card Riser" on page 99.
If the problem persists,

the riser card or system

board is faulty. See

"Getting Help" on

page 181.

E1A12 PCI Riser not

detected.
Check Riser.

One or both of the PCIe

risers are missing. This

prevents the system from

powering on.

Reinstall the missing

riser. See "Expansion

Card and Expansion-

Card Riser" on page 99.

E1A14 SAS cable A

failure. Check
connection.

SAS cable A is missing

or bad.

Reseat the cable. If the

problem persists,

replace cable.
If the problem persists,

see "Getting Help" on

page 181.