Dell PowerEdge R415 User Manual

Page 47

Advertising
background image

About Your System

47

PCIe Training
Error: Expected
Link Width is x,
Actual Link Width
is y.

Faulty or improperly

installed PCIe card in the

specified slot.

Reseat the PCIe card in the

specified slot number. See

"Troubleshooting Expansion

Cards" on page 165. If the

problem persists, see

"Getting Help" on page 181.

Plug & Play
Configuration
Error.

Error encountered in

initializing PCIe device;

faulty system board.

Install the NVRAM_CLR

jumper in the clear position

(pins 1 and 3) and reboot the

system. See Figure 6-1 for

jumper location. If the

problem persists, see

"Troubleshooting Expansion

Cards" on page 165.

Read fault.
Requested sector
not found.

The operating system cannot

read from the hard-drive,

optical drive, or USB device,

the system could not find a

particular sector on the disk,

or the requested sector is

defective.

Replace the optical medium,

USB medium or device.

Ensure that the SAS

backplane, USB, or SATA

cables are properly

connected. See

"Troubleshooting a USB

Device" on page 150,

"Troubleshooting an Optical

Drive" on page 161, or

"Troubleshooting a Hard

Drive" on page 163 for the

appropriate drive(s) installed

in your system.

SATA Port x
device not found.

There is no device connected

to the specified SATA port.

Information only.

Table 1-3. System Messages

(continued)

Message

Causes

Corrective Actions

R415HOM.book Page 47 Friday, September 24, 2010 9:37 AM