microprocessor(s) (see
"
E07F4
POST CPU SMI
SMI handler failed to initialize;
faulty system board.
Replace the system board (see
"
E07FA
TEMP CPU n
THERM
Specified microprocessor is out of
acceptable temperature range and
is operating at a reduced speed, or
frequency.
Ensure that the system cooling fans
are properly installed. If the problem
persists, replace the faulty fan(s)
(see "
"). If the problem
persists, ensure that the
microprocessor heat sinks are
properly installed. If the problem
persists, replace the faulty
microprocessor (see
"
E0876
POWER PS n
No power available from the
specified power supply; specified
power supply is improperly
installed or faulty.
Ensure that the power supplies are
properly installed. If the problem
persists, replace the faulty power
supply(ies) (see "
").
E0880
INSUFFICIENT PS
Insufficient power is being supplied
to the system; power supplies are
improperly installed, faulty, or
missing.
E0CB2
MEM SPARE BANK
Correctable errors threshold was
met in a memory bank: errors
were remapped to the spare bank.
Ensure that the memory modules are
properly installed. If the problem
persists, replace the faulty memory
module(s) (see "
E0CF1
MBE DIMM Bank n
Memory modules installed in the
specified bank are not the same
type and size; faulty memory
module(s).
Ensure that all banks contain
memory modules of the same type
and size and that they are properly
installed. If the problem persists,
replace the faulty memory module(s)
(see "
").
E0CF1
POST MEM 64K
Parity failure in the first 64 KB of
main memory.
Ensure that the memory modules are
properly installed. If the problem
persists, replace the faulty memory
module(s) (see "
E0CF1
POST NO MEMORY
Main-memory refresh verification
failure.
Ensure that all banks contain
memory modules of the same type
and size and that they are properly
installed. If the problem persists,
replace the faulty memory module(s)
(see "
").
E0CF5
LOG DISABLE SBE
Multiple single-bit errors on a
single memory module.
Ensure that the memory modules are
properly installed. If the problem
persists, replace the faulty memory
module(s) (see "
E0D76
DRIVE FAIL
Faulty or improperly installed hard
drive or RAID controller.
Ensure that the hard drives are
properly installed. If the problem
persists, replace the faulty hard
drive(s) (see "
"). If the
problem persists, replace the RAID
controller (see "
" and "
E0F04
POST CMOS
CMOS write/read failure; faulty
system board.
Replace the system board (see
"
E0F04
POST CPU SPEED
Microprocessor speed control
sequence failure.
Ensure that the microprocessors are
properly installed. If the problem
persists, replace the faulty
microprocessor(s) (see