Dell PowerVault 775N (Rackmount NAS Appliance) User Manual

Page 23

Advertising
background image

microprocessor(s) (see

"

Microprocessors

").

E07F4

POST CPU SMI

SMI handler failed to initialize;

faulty system board.

Replace the system board (see

"

System Board

").

E07FA

TEMP CPU n
THERM

Specified microprocessor is out of

acceptable temperature range and

is operating at a reduced speed, or

frequency.

Ensure that the system cooling fans

are properly installed. If the problem

persists, replace the faulty fan(s)

(see "

System Fans

"). If the problem

persists, ensure that the

microprocessor heat sinks are

properly installed. If the problem

persists, replace the faulty

microprocessor (see

"

Microprocessors

").

E0876

POWER PS n

No power available from the

specified power supply; specified

power supply is improperly

installed or faulty.

Ensure that the power supplies are

properly installed. If the problem

persists, replace the faulty power

supply(ies) (see "

Power Supplies

").

E0880

INSUFFICIENT PS

Insufficient power is being supplied

to the system; power supplies are

improperly installed, faulty, or

missing.

E0CB2

MEM SPARE BANK

Correctable errors threshold was

met in a memory bank: errors

were remapped to the spare bank.

Ensure that the memory modules are

properly installed. If the problem

persists, replace the faulty memory

module(s) (see "

Memory Modules

").

E0CF1

MBE DIMM Bank n

Memory modules installed in the

specified bank are not the same

type and size; faulty memory

module(s).

Ensure that all banks contain

memory modules of the same type

and size and that they are properly

installed. If the problem persists,

replace the faulty memory module(s)

(see "

Memory Modules

").

E0CF1

POST MEM 64K

Parity failure in the first 64 KB of

main memory.

Ensure that the memory modules are

properly installed. If the problem

persists, replace the faulty memory

module(s) (see "

Memory Modules

").

E0CF1

POST NO MEMORY

Main-memory refresh verification

failure.

Ensure that all banks contain

memory modules of the same type

and size and that they are properly

installed. If the problem persists,

replace the faulty memory module(s)

(see "

Memory Modules

").

E0CF5

LOG DISABLE SBE

Multiple single-bit errors on a

single memory module.

Ensure that the memory modules are

properly installed. If the problem

persists, replace the faulty memory

module(s) (see "

Memory Modules

").

E0D76

DRIVE FAIL

Faulty or improperly installed hard

drive or RAID controller.

Ensure that the hard drives are

properly installed. If the problem

persists, replace the faulty hard

drive(s) (see "

Hard Drives

"). If the

problem persists, replace the RAID

controller (see "

Integrated RAID

Controller

" and "

RAID Controller

Card

").

E0F04

POST CMOS

CMOS write/read failure; faulty

system board.

Replace the system board (see

"

System Board

").

E0F04

POST CPU SPEED

Microprocessor speed control

sequence failure.

Ensure that the microprocessors are

properly installed. If the problem

persists, replace the faulty

microprocessor(s) (see