E0F04
POST DMA INIT
DMA initialization failure; DMA
page register write/read failure.
Ensure that the memory modules are
properly installed. If the problem
persists, replace the faulty memory
module(s) (see "
E0F04
POST DMA REG
Faulty system board.
Replace the system board (see
"
E0F04
POST KYB CNTRL
Faulty keyboard controller; faulty
system board.
Replace the system board (see
"
E0F04
POST MEM RFSH
Main-memory refresh verification
failure.
Ensure that the memory modules are
properly installed. If the problem
persists, replace the faulty memory
module(s) (see "
E0F04
POST PIC REG
Master or slave PIC register test
failure.
Replace the system board (see
"
E0F04
POST SHADOW
BIOS-shadowing failure.
Ensure that the memory modules are
properly installed. If the problem
persists, replace the faulty memory
module(s) (see "
E0F04
POST SHD TEST
Shutdown test failure.
E0F04
POST SIO
Super I/O chip failure; faulty
system board.
Replace the system board (see
"
E0F04
POST TIMER
Programmable interval timer test
failure; faulty system board.
Replace the system board (see
"
E0F0B
POST ROM CHKSUM
Faulty or improperly installed
expansion card.
Ensure that the expansion cards are
properly installed. If the problem
persists, replace the faulty expansion
card(s) (see "
E0F0C
VID MATCH CPU n
Specified microprocessor is faulty,
unsupported, improperly installed,
or missing.
Ensure that the microprocessors are
properly installed. If the problem
persists, replace the faulty
microprocessor(s) (see
"
E10F3
LOG DISABLE
BIOS
BIOS disabled logging errors.
Check the SEL for details on the
errors.
E13F2
IO CHANNEL
CHECK
Faulty or improperly installed
expansion card; faulty system
board.
Ensure that the expansion cards are
properly installed. If the problem
persists, replace the faulty expansion
card(s) (see "
"). If
the problem persists, replace the
system board (see "
E13F4
PCI PARITY
E13F5
PCI SYSTEM
E13F8
CPU BUS INIT
Faulty or improperly installed
microprocessor or system board.
Ensure that the microprocessors are
properly installed. If the problem
persists, replace the faulty
microprocessor(s) (see
"
"). If the problem
persists, replace the system board
(see "
E13F8
CPU BUS PARITY
Faulty system board.
Replace the system board (see
"
E13F8
CPU MCKERR
Machine check error; faulty or
improperly installed
microprocessor; faulty system
board.
Ensure that the microprocessors are
properly installed. If the problem
persists, replace the faulty
microprocessor(s) (see
"
"). If the problem
persists, replace the system board
(see "
E13F8
HOST BUS
Faulty system board.
Replace the system board (see
"