Dell PowerVault 775N (Rackmount NAS Appliance) User Manual

Page 24

Advertising
background image

"

Microprocessors

").

E0F04

POST DMA INIT

DMA initialization failure; DMA

page register write/read failure.

Ensure that the memory modules are

properly installed. If the problem

persists, replace the faulty memory

module(s) (see "

Memory Modules

").

E0F04

POST DMA REG

Faulty system board.

Replace the system board (see

"

System Board

").

E0F04

POST KYB CNTRL

Faulty keyboard controller; faulty

system board.

Replace the system board (see

"

System Board

").

E0F04

POST MEM RFSH

Main-memory refresh verification

failure.

Ensure that the memory modules are

properly installed. If the problem

persists, replace the faulty memory

module(s) (see "

Memory Modules

").

E0F04

POST PIC REG

Master or slave PIC register test

failure.

Replace the system board (see

"

System Board

").

E0F04

POST SHADOW

BIOS-shadowing failure.

Ensure that the memory modules are

properly installed. If the problem

persists, replace the faulty memory

module(s) (see "

Memory Modules

").

E0F04

POST SHD TEST

Shutdown test failure.

E0F04

POST SIO

Super I/O chip failure; faulty

system board.

Replace the system board (see

"

System Board

").

E0F04

POST TIMER

Programmable interval timer test

failure; faulty system board.

Replace the system board (see

"

System Board

").

E0F0B

POST ROM CHKSUM

Faulty or improperly installed

expansion card.

Ensure that the expansion cards are

properly installed. If the problem

persists, replace the faulty expansion

card(s) (see "

Expansion Cards

").

E0F0C

VID MATCH CPU n

Specified microprocessor is faulty,

unsupported, improperly installed,

or missing.

Ensure that the microprocessors are

properly installed. If the problem

persists, replace the faulty

microprocessor(s) (see

"

Microprocessors

").

E10F3

LOG DISABLE
BIOS

BIOS disabled logging errors.

Check the SEL for details on the

errors.

E13F2

IO CHANNEL
CHECK

Faulty or improperly installed

expansion card; faulty system

board.

Ensure that the expansion cards are

properly installed. If the problem

persists, replace the faulty expansion

card(s) (see "

Expansion Cards

"). If

the problem persists, replace the

system board (see "

System Board

").

E13F4

PCI PARITY

E13F5

PCI SYSTEM

E13F8

CPU BUS INIT

Faulty or improperly installed

microprocessor or system board.

Ensure that the microprocessors are

properly installed. If the problem

persists, replace the faulty

microprocessor(s) (see

"

Microprocessors

"). If the problem

persists, replace the system board

(see "

System Board

").

E13F8

CPU BUS PARITY

Faulty system board.

Replace the system board (see

"

System Board

").

E13F8

CPU MCKERR

Machine check error; faulty or

improperly installed

microprocessor; faulty system

board.

Ensure that the microprocessors are

properly installed. If the problem

persists, replace the faulty

microprocessor(s) (see

"

Microprocessors

"). If the problem

persists, replace the system board

(see "

System Board

").

E13F8

HOST BUS

Faulty system board.

Replace the system board (see

"

System Board

").