Table 1-7. Environmental specifications (continued)

Parameter

Operating (see Note)

Storage

Shipping

Altitude (meters)

0 - 2,500

0 - 2,500

0 - 2,500

Note:

The operating environment of the library must not conflict with the media storage

requirements. The library can operate at elevated temperatures for an extended period.
However, the temperature might shorten the useful life of media that is stored in the
library. If media is stored in the library for more than 10 hours, the storage temperature
requirements for media are met. It is assumed that media stored in the library is
approximately 2 degrees above ambient temperature when the library is powered ON.

Table 1-8. Operational specifications

Parameter

Model S6H

Model S5H

Model S4H

Maximum storage
capacity

22.5 TB (56.2 TB with

2.5:1 compression)

13.5 TB (27 TB with

2:1 compression)

7.2 TB (14.4 TB with

2:1 compression)

Maximum number of
data cartridges

9 (including an optional I/O Station)

Drive types

Ultrium 6 Half High

Ultrium 5 Half High

Ultrium 4 Half High

Sustained native data
transfer rate

160 MB/s (320 MB/s

with 2:1

compression)

140 MB/s (280 MB/s

with 2:1

compression)

120 MB/s (240 MB/s

with 2:1

compression)

Interface

6 Gb/s SAS

3 Gb/s SAS

Note:

The Ultrium 4 Half-High tape drive in S4H libraries that are manufactured after

March 2011 support 6.0 Gb/s and a sustained native data rate of 120 Gb/s.

Table 1-9. Acoustical specifications

Parameter

Measurement

Idling acoustical noise sound power level
LwAD in Bels (1 Bel = 10 dB)

6.6

Maximum acoustical noise sound power
level LwAD in Bels (1 Bel = 10 dB)

6.8

Product environment

The TL1000 Tape Autoloader is designed to operate in a general business
environment.

The library meets the acoustical requirements for general business area category
2D. Category 2D states that the library can be installed a minimum of 4 m (13 ft.)
from a permanent work station.

To allow for service access, install the library a minimum of 0.9 m (3 ft.) from all
obstacles.

The library is a precision computer peripheral device. To ensure maximum
longevity of your library, locate the library away from dust, dirt, and airborne
particulates, as follows:

v

Keep the library away from high-traffic areas, especially if the floor is carpeted.
Carpeting harbors dust and walking on the carpet can cause the carpet fibers
and the dust to become airborne.

Chapter 1. Product description