Troubleshooting a wet system – Dell DX6000 User Manual

Page 158

Advertising
background image

158

Troubleshooting Your System

4 Ensure that the appropriate drivers are installed and the protocols are

bound. See the NIC's documentation.

5 Enter the System Setup program and confirm that the NIC ports are

enabled. See "Integrated Devices Screen" on page 64.

6 Ensure that the NICs, hubs, and switches on the network are all set to the

same data transmission speed and duplex. See the documentation for each

network device.

7 Ensure that all network cables are of the proper type and do not exceed the

maximum length.
If all troubleshooting fails, see "Getting Help" on page 189.

Troubleshooting a Wet System

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came
with the product.

1 Turn off the system and attached peripherals, and disconnect the system

from the electrical outlet.

2 Open the system. See "Opening the System" on page 83.
3 Disassemble components from the system. See "Installing System

Components" on page 79.
• Cooling shroud
• Hard drives
• SD cards
• USB memory key
• NIC hardware key
• Internal SD Module
• Expansion cards and both expansion-card risers
• Integrated storage controller
• iDRAC6 Enterprise card