37

I1910

Intrusion

detected.

Check chassis

cover.

System cover has been

removed.

Information only.

I1911

LCD Log Full.

Check SEL to

review all

Errors.

LCD overflow message. A

maximum of ten error

messages can display

sequentially on the LCD.

The eleventh message

instructs the user to check

the SEL for details on the

events.

Check the SEL for details

on the events.
Remove AC power to the

system for 10 seconds or

clear the SEL.

I1912

SEL full.

Review &

clear log.

The SEL is full of events

and is unable to log any

more.

Check the SEL for more

information and then

clear the SEL.

W1228

RAID

Controller

battery

capacity <

24hr.

Warns predictively that the

RAID battery has less than

24 hours of charge left.

Allow RAID battery to

charge to greater than 24

hours of sustained charge.
If problem persists,

replace the RAID battery.

See "Installing a RAID

Battery" on page 116.

W1627

Power

required >

PSU wattage.

Check PSU and

config.

The system configuration

requires more power than

what the power supply can

provide.

Turn off power to the

system, reduce the

hardware configuration or

install higher-wattage

power supplies, and then

restart the system.

W1628

Performance

degraded.

Check PSU and

system

configuration.

The system configuration

requires more power than

what the power supply can

provide, but it can boot if

throttled.

Turn off power to the

system, reduce the

hardware configuration or

install higher-wattage

power supplies, and then

restart the system.