About Your System

The following

DIMMs should

match

in

geometry:

x,x,...

Invalid memory

configuration. The specified

memory modules do not

match in size, number of

ranks, or number of data

lanes.

Ensure that the memory

modules are installed in a

valid configuration.

See "General Memory

Module Installation

Guidelines" on page 131.

The following

DIMMs should

match

in rank

count:

x,x,...

The following

DIMMs should

match in size:

x,x,...

The following

DIMMs should

match

in size

and geometry:

x,x,...

The following

DIMMs should

match

in size

and rank count:

x,x,...

Thermal sensor

not detected on

x.

A memory module without a

thermal sensor is installed in

the specified memory slot

Replace the memory module.

See "System Memory" on

page 130.

Time-of-day

clock stopped.

Faulty battery or faulty chip. See "Troubleshooting the

System Battery" on page 160.

Time-of-day not

set - please run

SETUP program.

Incorrect Time or Date

settings; faulty system

battery.

Check the Time and Date

settings. See "Using the

System Setup Program and

UEFI Boot Manager" on

page 57. If the problem

persists, replace the system

battery. See "System Battery"

on page 143.

Table 1-2. System Messages