Server Installations and Upgrades—TIGW1U server

4. Connect the power and data cables back onto the interposer board.
5. If this is the only change you are making, attach the front bezel and cover and

reconnect the power to the chassis.

3.5.2

Replacing a Fan Assembly

Caution:

Your server does not have hot-swappable fans. Before replacing any of the fans, you

must first take the server out of service, turn off all peripheral devices connected to the

system, turn off the system by pressing the power button, and unplug the AC power

cord from the system or wall outlet.

The replacement/spare fan set consists of one PCI fan and four dual-rotor CPU fans

plus enough resilient fan bumpers for all five fans. The bumpers are used to isolate fan

vibration from the rest of the system.

Figure 41.

Installing the Drive Tray with Optical Drive Attached into the Server

A

B

TS000223

Figure 42.

PCI Fan and Four-Fan Set (with Bumpers Installed)

AF000831