Kontron TIGW1U Carrier Grade Server User Manual

Page 57

Advertising
background image

Kontron Carrier Grade Server TIGW1U

December 2009

Product Guide, rev. 1.3

57

Server Installations and Upgrades—TIGW1U server

5. Disconnect these cables from the SFP board:

— Front panel data
— Front panel USB
— All fan power cables
— Flex cable
— Optical device power cable
— Power interconnect to PDB

6. Remove the screws (“A”).
7. Gently work the SFP board backward (“B”), toward the rear of the chassis to

disengage the light pipe from behind the front control panel bezel.

8. Pull the front panel board up over the placement pegs ("C") and lift it from the

chassis.

9. Remove any other components you have installed on the SFP board, such as a

Intel

®

RAID Smart Battery, Intel

®

RAID Activation Key, and mini-DIMM. Set them

aside for re-installation on the new replacement SFP board.

Figure 46.

Removing the SFP Board

A

C

TS000205

B

C

Advertising