6 diagnostics pass but the connection fails, 7 the server hangs when the drivers are loaded, 10 system boots when installing a pci card – Kontron TIGW1U Carrier Grade Server User Manual

Page 81: Diagnostics pass but the connection fails, The server hangs when the drivers are loaded, Installed

Advertising
background image

Kontron Carrier Grade Server TIGW1U

December 2009

Product Guide, rev. 1.3

81

Troubleshooting—TIGW1U server

 Make sure you are using the correct and the current drivers. Go to

http://

us.kontron.com/support/

for a link to the drivers.

 Make sure the driver is loaded and the protocols are bound.

 Make sure the hub port is configured for the same duplex mode as the network

controller.

 Make sure the correct networking software is installed.

 If you are directly connecting two servers (without a hub), you will need a

crossover cable.

 Check the network controller LEDs next to the NIC connectors.

5.4.6

Diagnostics Pass but the Connection Fails

 Make sure the network cable is securely attached.

 Make sure you specify the correct frame type in your NET.CFG file.

5.4.7

The Server Hangs When the Drivers are Loaded

 Certain drivers may require interrupts that are not shared with other PCI drivers.

For these drivers, it may be necessary to alter settings so that interrupts are not

shared. See the documentation that came with your PCI card(s) for information on

changing interrupts.

5.4.8

The Controller Stopped Working When an Add-in Adapter was

Installed

 Make sure the cable is connected to the port from the onboard network controller.

 Make sure your BIOS is current. Go to

http://us.kontron.com/support/

for a link to

the current version.

 Make sure the other adapter supports shared interrupts. Make sure your operating

system supports shared interrupts.

 Try reseating the add-in adapter.

5.4.9

The Add-in Adapter Stopped Working Without Apparent Cause

 Try reseating the adapter first; then try a different slot if necessary.

 The network driver files may be corrupt or deleted. Delete and then reinstall the

drivers.

 Run the diagnostics.

5.4.10

System Boots When Installing a PCI Card

System Server Management features require full-time “standby” power. This means

some parts of the system have power going to them whenever the power cord is

plugged in, even if you have turned the system power off with the power button on the

front panel. If you install a PCI card with the power cord

plugged in, a signal may be

sent to command the system to boot. Before installing a PCI card, you should always:

1. Turn off the server power by using the power button on the front of the system.
2. Unplug the power cord

from the server.

Advertising