Server Installations and Upgrades—TIGW1U server

5. Remove the heat sink(s) and processor(s). For instructions, see

Section 3.4.4.2,

“Removing a Processor” on page 38

.

6. Remove the four-fan assembly, including the bracket.
7. Disconnect all cables from the server board.
8. Remove the screws that attach the server board to the chassis. (“A” in

Figure 52

)

9. Tilt the server board and lift it from the chassis. (“B”) Use caution in pulling it out

from beneath the Serial B connector at the rear of the chassis.

3.5.6.2

Installing the Server Board Back into the Chassis

1. Set the replacement board into place (“B” in

Figure 53

), using caution to make sure

that no cables are pinched under the board. Insert the rear edge of the board first,

and line up the I/O ports at the rear of the system.

2. Make sure the standoff locations line up correctly and reinsert the seven screws

removed previously. (“A”)

Figure 52.

Removing the Server Board

TS000209

A

B