Troubleshooting—TIGW1U server

 Make sure you have not exceeded the power budget for the server. Go to

http://

us.kontron.com/support/

for a link to software to check your power budget.

5.5

LED Information

The Intel

®

Server Board S5000PHB server board includes LEDs that can aid in

troubleshooting your system.

Table 8

defines these LEDs with a description of their use.

5.6

BIOS Error Messages

When a recoverable error occurs during the POST, the BIOS displays an error message

describing the problem. See

Table 9

.

Table 8.

LED Definitions

LED Name

Function

Location

Color

Notes

ID

Aid in server

identification from

the back panel

Control panel and

board rear left

corner

Blue

Press ID LED button or user

Server Management

software to turn on the LED.

System fault

Visible fault warning

Control panel and

board rear left

corner

Green or

Amber

Green = No Fault
Green blinking = degraded
Amber = critical error or

non-recoverable
Amber blinking = non-

critical error

ATA drive activity

Control panel

Control panel

Green

Blinking = Activity. No action

required.

Memory fault 1–6

Identify failing

memory module

DIMM end rear of

board

Amber

On = Fault

Diagnostic LEDs.

1–4 (LSB, bit1,

bit2, MSB)

Displays port 80

POST codes

Center back edge

of board

Each LED can

be Off, Green,

Amber, Red

See the POST code table

CPU 1 & 2 Fan

Fault

Identify fan failure

Front center board

Amber

On = Fault

CPU 1 & 2 Fault

Identify processor

failure

1” behind

processor socket

Amber

On = Fault

5v Standby

Identify 5v standby

power on state

Front left board

Amber

On = 5v standby power on

Power LED

Identify the power

state of the system

Control Panel

Green

Off = Power is off (off or S5)
On = Power on or S0)
Slow Blink = Low power

state (S1 – S3)

Table 9.

BIOS Error Messages (Sheet 1 of 2)

Error Message

Explanation

GA20 Error

An error occurred with Gate A20 when switching to protected

mode during the memory test.

Pri Master HDD Error

Pri Slave HDD Error

Sec Master HDD Error

Sec Slave HDD Error

Could not read sector from corresponding drive.

Pri Master Drive - ATAPI Incompatible Pri

Slave Drive - ATAPI Incompatible Sec

Master Drive - ATAPI Incompatible Sec

Slave Drive - ATAPI Incompatible

Corresponding drive is not an ATAPI (Advanced Technology

Attachment Packet Interface) device. Run Setup to make sure

device is selected correctly.

A: Drive Error