TIGW1U server—Server Installations and Upgrades

Kontron Carrier Grade Server TIGW1U

Product Guide, rev. 1.3

December 2009

62

Figure 51.

Installing the PDB

3. Connect all power cables and the edge connector (“B”).
4. Install the PCI fan air duct and the chassis cover.

3.5.6

Replacing the Server Board

The Carrier Grade Server TIGW1U uses the Intel

®

Server Board S5000PHB server

board. To replace the server board, the following components must be removed:

All components on the server board:

• Heat sink(s)
• Processor(s)
• All DIMMs
• PCI riser assembly
• Four-fan assembly

To replace the server board, use the following instructions.

Caution:

Before replacing a board, you must first take the server out of service, turn off all

peripheral devices connected to the system, turn off the system by pressing the power

button, and unplug the power cord from the system or wall outlet.

When handling this board or any of the components on it, observe safety and ESD

precautions. See

Appendix A, “Safety Information”

for more information.

3.5.6.1

Removing the Server Board

1. Power down the server system and unplug all peripheral devices and the power

cable.

2. Remove the chassis cover and processor air duct.
3. Remove the PCI riser assembly. For instructions, see

Section 3.4.5.1, “Removing

the PCI Riser Card Assembly” on page 42

.

4. Remove all DIMMs. For instructions, see

Section 3.4.3.2, “Removing DIMMs” on

page 37

.

TS000208

B

A

C