Service OAM

9145E NID Software User’s Manual

Maintenance Associations

127

7. You can view or modify the peer MEPs list. Type 4 and press <Enter>. The Maintenance

Associations Peer MEPs screen opens. Up to 128 peer MEPs can be configured for an
MA or a MEG. The maximum number of peer MEPs per system is 256.

a. To add a peer MEP, type 1 and press <Enter>. You are prompted for the MEP ID

number. Type the number and press <Enter>.

b. To remove a peer MEP, type 2 and press <Enter>. You are prompted for the MEP ID

number. Type the number and press <Enter>.

c. When all the peer MEPs have been configured, type A to accept and press <Enter>.

d. Press <Esc> to return to the Maintenance Associations Attributes screen

5. You can change the Permissions (Sender ID). Select None, Chassis, Manage, Chassis-

Manage, or Defer, and press <Enter>.

6. When you are finished, type A to accept the settings and press <Enter>.

7. Press <Esc> to return to the Maintenance Association List screen.

Figure 11-14. Maintenance Association Attributes screen

Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
Model 9145E-104-0-0 V3.00 F214 00:25:46

----------------------MAINTENANCE ASSOCIATION ATTRIBUTES-----------------------

MD ID: 2 Level: 0
MA ID: 2 Name: port-layer

1) CCM Interval: 1 sec

VLAN Tag Type: NONE
VLAN List: N/A

2) Add VLAN to VLAN List.
3) Remove VLAN from VLAN List.

4) View/Modify Peer MEPs list.
5) Permissions (Sender ID): None

Select [1-5] for attributes:

------------------------------------Messages-----------------------------------