3 delete a maintenance end point, 4 modify a maintenance end point, Delete a maintenance end point – CANOGA PERKINS 9145E NID Software Version 3.0 User Manual

Page 149: Modify a maintenance end point

Advertising
background image

Service OAM

9145E NID Software User’s Manual

Maintenance End Points

135

11.6.3 Delete a Maintenance End Point

When you delete a Y.1731 Maintenance End Point, it is also deleted from the AIS client list.

1. On the Maintenance End Point List screen (Figure 11-18), type D and press <Enter>. The

current MEP is highlighted.

2. Press <Space> to scroll through the list and highlight the entry you wish to delete.

3. Press <Enter> to delete the highlighted MEP.

11.6.4 Modify a Maintenance End Point

1. On the Maintenance End Point List screen (Figure 11-18), type E and press <Enter>. The

current MEP is highlighted.

2. Press <Space> to scroll through the list and highlight the entry to modify.

3. When the MEP you want to modify is highlighted, press <Enter>. The Maintenance End

Point Attributes screen for that MEP opens (Figure 11-21 for 802.1ag or Figure 11-22 for
Y.1731).

4. To change the Admin Status, type 1 and press <Enter>. Select Enabled or Disabled and

press <Enter>.

5. To change CCM Transmit Status, type 2 and press <Enter>. Select Enabled or Disabled

and press <Enter>.

6. To change the Primary VLAN ID, type 3 and press <Enter>. C-Tag indicates that ethernet

frames (CCMs, LBMs, LBRs, LTMs, LTRs) are tagged for customers. None means that
the frames are not tagged. Select a VLAN Tag Type and press <Enter>.

7. To change the fault alarm detect time, type 4 and press <Enter>. This is the time that

defects must be present before a fault alarm is issued. Type an entry between 2500 and
10000 milliseconds and press <Enter>.

When a defect is detected, a fault alarm is raised. When the defect is no longer present, the fault
alarm is not cleared immediately. The system waits for the fault alarm clear time before clearing
the alarm.

8. To change the fault alarm clear time, type 5 and press <Enter>. This is the time that

defects must be absent before a fault alarm is reset. Type an entry between 2500 and
10000 milliseconds and press <Enter>.

9. To change the CCM/LTM Priority, type 6 and press <Enter>. This is the priority parameter

(P-bits) for CCMs and LTMs transmitted by the MEP. Type a number from 0 to 7 and
press <Enter>.