9145E NID Software User’s Manual

Service OAM

Maintenance End Points

134

5. In the Admin Status field, select Enabled or Disabled and press <Enter>. The Direction

field is highlighted.

6. In the Direction field, select Up to identify a MEP that transmits CFM PDUs towards, and

receives them from, the direction of NID interworking. Select Down to identify a MEP that
receives CFM PDUs from, and transmits them towards, the direction of the wire. Press
<Enter>. The Port field is highlighted.

7. In the Port field, select User or Network.

8. To accept the new Maintenance End Point settings, type A and press <Enter>. The Main-

tenance End Point Attributes screen (Figure 11-21 for 802.1ag or Figure 11-22 for Y.1731)
opens.

9. To modify an attribute value, type the number of the attribute and press <Enter>, or press

<Esc> to return to the Maintenance End Point List screen.

Figure 11-19. Create a New Maintenance End Point screen (Y.1731)

Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
Model 9145E-104-0-0 V3.00 F214 05:15:27
----------------------CREATE A NEW MAINTENANCE END POINT------------------------

1) MA ID 0
MEP ID: 0
2) Admin Status: Disabled
3) Direction: Down
4) Port: User

Enter number in range 1 - 65535, or (CTRL-L) to select from list.