2 monitoring a loopback request, 7 maintenance intermediate points, 1 display maintenance intermediate points – CANOGA PERKINS 9145E NID Software Version 3.0 User Manual

Page 160: Monitoring a loopback request, Maintenance intermediate points, Display maintenance intermediate points

Advertising
background image

9145E NID Software User’s Manual

Service OAM

Maintenance Intermediate Points

146

11.6.7.2 Monitoring a Loopback Request

1. To stop current Loopback processing, on the Loopback Monitoring screen (Figure 11-28

for unicast, Figure 11-29 for sweep, or Figure 11-30 for multicast), type S and press
<Enter>.

2. To send another Loopback Request, type R and press <Enter>. The Loopback Request

screen (Figure 11-31) opens.

3. To see more Multicast Loopback results, type N and press <Enter>.

4. Press <Esc> to return to the Maintenance End Point Attributes screen.

11.7 Maintenance Intermediate Points

Maintenance Intermediate Points (MIPs) are intermediate nodes within a Maintenance Domain or
Maintenance Entity Group. Up to 128 MIPs can be configured in a 9145E NID device.

11.7.1 Display Maintenance Intermediate Points

To display a list of existing MIPs, on the SOAM Configuration screen (Figure 11-6), type 6 and
press <Enter>. The Maintenance Intermediate Point List screen (Figure 11-32) opens.

Figure 11-31. Maintenance Intermediate Point List screen

Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
Model 9145E-104-0-0 V3.00 F214 05:15:27
---------------------MAINTENANCE INTERMEDIATE POINT LIST-----Display 1 - 3 of 3-

MIP ID LEVEL TYPE PORT MD/MEG NAME
1 0 802.1ag USER 2/
20 7 Y.1731 NETWORK 101/ag-comp-101
21 3 802.1ag NETWORK 1/Domain 1 (service)

Select [(F)irst, (P)rev, (N)ext, (L)ast] to change pages,
(A)dd new, (D)elete, (E)dit, ESC to return:

------------------------------------Messages-----------------------------------

Advertising