System Configuration
9145E NID Software User’s Manual
IP/SNMP Agent Configuration
17
Figure 3-9 V1-Trap or V2c-Trap Notification Type Parameter
•
If V2c-Inform was selected (Figure 3-10):
a. Enter the Community Name.
b. Accept or revise the Retries parameter (default is 3).
c. Accept or revise the Timeout in Seconds parameter (default is 5).
d. Press Enter and then press Esc to return to the Trap Table menu (Figure 3-7).
•
If V3-Trap was selected (Figure 3-11):
a. Use the Space Bar to select the Security Name and press Enter.
b. Use the Space Bar to select the Security Level (No Auth/No Priv, Auth/No Priv,
or Auth/Priv) and press Enter.
c. Press Esc to return to the Trap Table menu (Figure 3-7).
Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
Model 9145E-101-3-0 V43.08 F211 15:52:50
----------------------------------EDIT TRAP/NOTIFICATION TYPE------------------
IP Address : 172.016.150.014
Trap/Notification Port : 162
Notification Type : V1-Trap
1. Community Name : public
Select [1]:
------------------------------------Messages-----------------------------------