CANOGA PERKINS 9145E NID Software Version 3.0 User Manual

Page 56

Advertising
background image

9145E NID Software User’s Manual

Diagnostics

PING Generation

42

7.

When finished setting up the PING Generation screen (Figure 4-5) entries, select Start Ping
(7) and press Enter. The PING test starts.

8.

When the test is complete, press Esc to return to the PING Generation screen.

Figure 4-4 PING Generation Screen

Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
Model 9145E-101-3-0 V43.08 F211 11:20:59
-------------------------------PING GENERATION---------------------------------

1) Ping to Address : 0.0.0.0
2) Ping from Address : Auto Selection
3) Ping Count : 0
4) Ping VLAN ID : 0
5) Ping Payload Size (40 - 9950) : 40
6) Ping DF Bit : Clear
7) Start Pinging

Select [1-7]:

------------------------------------Messages-----------------------------------

Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
Model 9145E-101-3-0 V43.08 F211 11:20:59

-------------------------------PING GENERATION---------------------------------

PING in progress

Ping Address : 172.16.2.35

Ping Count : 5

Ping VLAN ID : 0

Pinging 172.16.2.35 from 172.16.142.130 with 40 bytes.

Request timed out, Seq #0

5 packets transmitted, 0 packets received, 100.000% packet loss

round-trip (No round-trip packets received)

------------------------------------Messages-----------------------------------