11.7.2 Create a Maintenance Intermediate Point

1. On the Maintenance Intermediate Point List screen (Figure 11-32), type A and press

<Enter>. You are prompted to enter A for 802.1ag or Y for Y.1731.

2. Type A or Y and press <Enter>. The Create a New Maintenance Intermediate Point

screen (Figure 11-33 for 802.1ag or Figure 11-34 for Y.1731) opens. The MD/MEG ID
field is highlighted.

3. Type an MD ID (for 802.1ag) or MEG ID (for Y.1731) and press <Enter>. (To view a list of

MD/MEGs, press CTRL-L, type S to select, and press <Enter>). The MIP ID field is high-
lighted.

4. Type a MIP ID and press <Enter>. The Admin Status field is highlighted.

5. In the Admin status field, select Enabled or Disabled and press <Enter>. The Port field is

highlighted.

6. In the Port field, select User or Network and press <Enter>.

7. To accept the new Maintenance Intermediate Point settings, type A and press <Enter>.

The Maintenance Intermediate Point Attributes screen (Figure 11-35 for 802.1ag or Fig-
ure 11-36 for Y.1731) opens.

8. To modify an attribute value, type the number of the attribute and press <Enter>, or press

<Esc> to return to return to the Maintenance Intermediate Point List screen.

Figure 11-32. Create a New Maintenance Intermediate Point screen (802.1ag)

Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
Model 9145E-104-0-0 V3.00 F214 05:15:27
-----------------CREATE A NEW MAINTENANCE INTERMEDIATE POINT--------------------

1) MD ID 0
2) MIP ID: 0
3) Admin status: Disabled
4) Port: User

Enter number in range 1 - 65535, or (CTRL-L) to select from list.

------------------------------------Messages-----------------------------------