3 delete a maintenance entity group, 4 modify a maintenance entity group, Delete a maintenance entity group – CANOGA PERKINS 9145E NID Software Version 3.0 User Manual

Page 145: Modify a maintenance entity group

Advertising
background image

Service OAM

9145E NID Software User’s Manual

Maintenance Entity Groups

131

11.5.3 Delete a Maintenance Entity Group

When you delete a Maintenance Entity Group, all MEPs/MIPs associated with it are also deleted
from the AIS client lists.

1. On the Maintenance Entity Group List screen (Figure 11-15), type D and press <Enter>.

The current Maintenance Entity Group is highlighted.

2. Press <Space> to scroll through the list and highlight the entry you wish to delete.

3. Press <Enter> to delete the highlighted Maintenance Entity Group. You are prompted to

confirm the deletion.

11.5.4 Modify a Maintenance Entity Group

1. On the Maintenance Entity Group List screen (Figure 11-15), type E and press <Enter>.

The current MEG is highlighted.

2. Press <Space> to scroll through the Maintenance Entity Groups and highlight a MEG to

modify.

3. When the item you want to modify is highlighted, press <Enter>. The Maintenance Entity

Group Attributes screen (Figure 11-17) opens.

4. To change the CCM interval, type 1 and press <Enter>. The CCM interval is the interval at

which CCMs are sent by a MEP. Select 1 sec, 10 sec, or 100 ms, and press <Enter>.

NOTE:No more than two MEPs at 100msec are supported. Typically, these

MEPs are used at MEG level 0 to monitor the physical line.

5. To add a VLAN to the VLAN list of this MEG, type 2 and press <Enter>. You are prompted

to type a new VLAN ID. Type the VLAN ID and press <Enter>. The VLAN appears in the
list. Up to four VLANs can be added for each MA.

6. To remove a VLAN from the list, type 3 and press <Enter>. You are prompted to type the

number of the VLAN to remove. Type the VLAN number and press <Enter>.

Some restrictions apply to modifying and deleting VLANs:

• The first VLAN is the primary VLAN and cannot be modified.

• To delete the primary VLAN, you must delete all VLANs in the list and create a

new list.

• If a VLAN list is shared by two or more MAs/MEGs, it cannot be modified from this

user interface.

7. You can view or modify the peer MEPs list. Type 4 and press <Enter>. The Maintenance

Entity Group Peer MEPs screen opens.

a. To add a peer MEP, type 1 and press <Enter>. You are prompted for the MEP ID

number. Type the number and press <Enter>.

Advertising