Service OAM
9145E NID Software User’s Manual
Maintenance Entity Groups
131
11.5.3 Delete a Maintenance Entity Group
When you delete a Maintenance Entity Group, all MEPs/MIPs associated with it are also deleted
from the AIS client lists.
1. On the Maintenance Entity Group List screen (Figure 11-15), type D and press <Enter>.
The current Maintenance Entity Group is highlighted.
2. Press <Space> to scroll through the list and highlight the entry you wish to delete.
3. Press <Enter> to delete the highlighted Maintenance Entity Group. You are prompted to
confirm the deletion.
11.5.4 Modify a Maintenance Entity Group
1. On the Maintenance Entity Group List screen (Figure 11-15), type E and press <Enter>.
The current MEG is highlighted.
2. Press <Space> to scroll through the Maintenance Entity Groups and highlight a MEG to
modify.
3. When the item you want to modify is highlighted, press <Enter>. The Maintenance Entity
Group Attributes screen (Figure 11-17) opens.
4. To change the CCM interval, type 1 and press <Enter>. The CCM interval is the interval at
which CCMs are sent by a MEP. Select 1 sec, 10 sec, or 100 ms, and press <Enter>.
NOTE:No more than two MEPs at 100msec are supported. Typically, these
MEPs are used at MEG level 0 to monitor the physical line.
5. To add a VLAN to the VLAN list of this MEG, type 2 and press <Enter>. You are prompted
to type a new VLAN ID. Type the VLAN ID and press <Enter>. The VLAN appears in the
list. Up to four VLANs can be added for each MA.
6. To remove a VLAN from the list, type 3 and press <Enter>. You are prompted to type the
number of the VLAN to remove. Type the VLAN number and press <Enter>.
Some restrictions apply to modifying and deleting VLANs:
• The first VLAN is the primary VLAN and cannot be modified.
• To delete the primary VLAN, you must delete all VLANs in the list and create a
new list.
• If a VLAN list is shared by two or more MAs/MEGs, it cannot be modified from this
user interface.
7. You can view or modify the peer MEPs list. Type 4 and press <Enter>. The Maintenance
Entity Group Peer MEPs screen opens.
a. To add a peer MEP, type 1 and press <Enter>. You are prompted for the MEP ID
number. Type the number and press <Enter>.