KEYENCE LJ-H1W User Manual

Page 58

Advertising
background image

Profile Storage

4-20

LJ-H1W-M-NO4-E

(4)[Delete profile] button

Deletes the displayed profile data.

(5)[Profile storage settings] button

Displays the [Profile storage settings] dialog box.

Settings for profile storage in the controller are configured here.

(6)[Read storage data] button

Reads the profile data in the connected controller on LJ-Navigator.

(7)No. of storage profiles

Displays the number of profiles that are stored on the controller.

(8)Present status

Displays the current operation status for the controller.

Target profile

Select the profile to store.

Setting range: Head A, Head B, Both heads, Calculation profile

Note

Note

When "Calculation" is selected for the profile setting and junction (vertical) or junction

(horizontal) is selected, select "Both heads" for the display profile.

No. of profiles

Set the number of profiles to be stored.

Setting range: 1 to 1024

Storage parameters

Select the conditions for storing the profile.

Setting range: Always, NG, Manual

All reception

Receives all of the storage settings (program Nos. 0 to 15 and environment settings)

from the controller.

Single reception

Receives the storage settings from a single, selected program No.

All transmission

Sends all of the storage settings (program Nos. 0 to 15 and environment settings)

that are being edited from LJ-Navigator to the controller.

Single sending

Sends the storage settings from a single, selected program No.

Close

Closes the [Profile storage settings] dialog box.