Error Message List

Appendix-12

LJ-H1W-M-NOA-E

Common
settings

The measurement value exceeds the
setting range.
Set the value between ( ) and ( ).

* The values displayed within the

parentheses ( ) vary depending on the
units and the minimum display unit.

Set the measurement value within the
displayed range.

Page 5-10

The value for output voltage exceeds the
setting range.
Set the value between -10.500 and
10.500.

Set the value for output voltage between
-10.500 and 10.500.

Page 5-14

The amount of storage data exceeds the
setting range.
Set the value between 1 and 65,536.

Set the amount of storage data between 1
and 65,536.

Page 5-15

The number of profiles exceeds the setting
range.
Set the value between 1 and 1024.

Set the number of profiles between 1 and
1024.

Page 5-16

Set the span value between -10 and 10.

Set the span value in the range of -10 and
10.

Page 5-8

The same values cannot be set for the
input values.

Set different values for the input values.

Page 5-10

Program name
setting

The length of the program name exceeds the
setting range.
Set a name with 16 or fewer characters.

Set the program name to 16 or fewer
characters.

Page 3-2

Environment
settings

The IP address exceeds the setting range.
Set the value between 0 and 255.

Set the IP address to groups of numbers
between 0 and 255.

Pages 1-8,
5-20

The gateway exceeds the setting range.
Set the value between 0 and 255.

Set the gateway to groups of numbers
between 0 and 255.

Page 5-20

The subnet mask exceeds the setting
range.
Set the value between 0 and 255.

Set the subnet mask to groups of numbers
between 0 and 255.

Page 5-20

The strobe time exceeds the setting range.
Set the value between 2 and 100.

Set the strobe time between 2 and 100.

Page 5-20

View
measurement
value

Failed to acquire measurement value.

• Set the controller to "Measurement

screen (Measuring)".

• Check that communication is possible

between the computer and the controller.

Page 4-2

View profile

Failed to acquire profile.

• Set the controller to "Measurement

screen (Measuring)".

• Check that communication is possible

between the computer and the controller.

Page 4-6

Data
storage

Failed to acquire storage data.

• Check whether values can be measured

with the controller.

• Check that communication is possible

between the computer and the controller.

Pages
1-12,
1-16,
1-19

The settable range is from 1 to 65,536.

Set the number of data points for data
storage between 1 and 65,536.

Page 4-13

Data cannot be acquired.

Store measurement data in the controller.

Page 4-12