KEYENCE LJ-H1W User Manual

Page 94

Advertising
background image

Error Message List

Appendix-10

LJ-H1W-M-NOA-E

Head setting

The value for delay count exceeds the
setting range.
Set the value between ( ) and ( ).

* The values displayed within the

parentheses ( ) vary depending on the
sampling count.

Set the delay count between 0 and 99,
depending on the sampling count.

Page 5-3

The maximum value for Manual exceeds the
setting range.
Set the value between 1 and 99.

Set the maximum value for Manual of the
laser intensity between 1 and 99.

Page 5-3

The minimum value for Manual exceeds
the setting range.
Set the value between ( ) and ( ).

* The values displayed within the

parentheses ( ) vary depending on the
maximum value for Manual.

Set the minimum value for Manual of the
laser intensity between 1 and 99 and below
the maximum value for Manual of the laser
intensity.

Page 5-3

The number of times for profile alarm
exceeds the setting range.
Set the value between 0 and 255.

Set the number of times for profile alarm
between 0 and 255.

Page 5-3

The value for correction angle exceeds the
setting range.
Set the value between -10

°

and 10

°

.

Set the correction angle between -10

°

and

10

°

.

Page 5-3

The value for height correction exceeds
the setting range.
Set the value between 0 and 10.

Set the height correction between 0x and
10x.

Page 5-3

Profile setup

The amount of movement in the X direction
exceeds the range.

Set the amount of movement in the X direction
within the range for X measurement width.

Page 5-5

The amount of movement in the Z direction
exceeds the range.

Set the amount of movement in the Z
direction within the range for Z measurement
width.

Page 5-5

The value for delay count between the
heads exceeds the setting range.
Set the value between 0 and 1023.

Set the value for delay count between the
heads between 0 and 1023.

Page 5-5

Failed to acquire profile for Head A.

• Check whether communication is possible

between the controller and computer.

• Set the controller to "Measurement

screen (Measuring)".

Pages 4-7,
5-5

Failed to acquire profile for Head B.

• Check whether communication is possible

between the controller and computer.

• Set the controller to "Measurement

screen (Measuring)".

Pages 4-7,
5-5

Master
registration

Failed to acquire profile for Head A.

• Check whether communication is possible

between the controller and computer.

• Set the controller to "Measurement

screen (Measuring)".

Pages 4-7,
5-5

Failed to acquire profile for Head B.

• Check whether communication is possible

between the controller and computer.

• Set the controller to "Measurement

screen (Measuring)".

Pages 4-7,
5-5

Item

Error message

Measure

Reference

Advertising