KEYENCE LJ-H1W User Manual

Page 62

Advertising
background image

Profile Storage

4-24

LJ-H1W-M-NO4-E

Starting profile storage

1

Connect LJ-Navigator and the controller, check that communication can be established, and then

measure the measurement target.

"Connecting via USB" (Page 1-12)

"Connecting via Ethernet" (Page 1-16)

"Connecting via RS-232C" (Page 1-19)

2

Set the storage settings to [Profile storage] in the common settings for the controller.

3

Click the [Profile storage] icon of the tool bar.

The [Profile storage] window appears.

4

Click the [Start storage] button.

The controller starts storing the profile.

When the number of stored profiles matches the value set for [No. of profiles] in the [Profile storage settings]

dialog box, the storage stops automatically.

Reference

• The storage timing depends on the trigger settings and data output timing settings. Data can be stored at a specified timing

when performing continuous storage. If you want to stop the data storage in the middle of storage, click the [Stop storage]

button.

• If communication is not possible between LJ-Navigator and the controller, or if a head is not connected, the following dialog

appears shortly after clicking the [Start storage] button or the [Read storage data] button.

Check the connection between each head and between LJ-Navigator and the controller. Check that the controller is set to

[Profile storage].

Advertising