10.4.

Description Of The Item "Data Output Mode"

The parameter setting of "Data output mode (

prt

)" applies to the performance when the "Data

memory (

data

)" parameter is set to "

2

" (to store the weighing data) and when the data is

transmitted using the RS-232C interface.

Key mode

When

the

PRINT

key is pressed with the stabilization indictor turned on, the balance outputs or

stores the weighing data and the display blinks one time.

Required

setting

dout

prt 0

Key

mode

Auto print modes A and B

When the displayed value is stable and the conditions of "Auto print polarity", "Auto print

difference" and reference value are met, the balance outputs or stores the weighing data.

When

the

PRINT

key is pressed with the stabilization indictor turned on, the balance outputs or

stores the data and the display blinks one time.

Auto print mode A

Example

For

weighing

each time a sample is placed and removed, with "

ar-d

" set

to "

1

" (to adjust zero after the data is output).

Required

setting

dout

prt 1

Auto

print

mode

A (reference = zero)

dout

ap-p

Auto print polarity

dout

ap-b

Auto print difference

dout

ar-d 1

Zero after output

Auto print mode B

Example

For weighing while a sample is added.

Required

setting

dout

prt 2

Auto print mode B (reference = last stable value)

dout

ap-p

Auto

print

polarity

dout

ap-b

Auto

print

difference

Stream mode

The balance outputs the weighing data continuously regardless of the display condition. When the

display refresh rate is set to 5 times / second (5pd 0), the data output rate is also set to the same
5 times / second. The display does not blink in this mode. The interval memory mode is used
when the "Data memory (

data

)" parameter is set to "

1

" (to store the weighing data).

Example

For

monitoring data on a computer.

Required

setting

dout

prt 3

Stream mode

dout

data 0

Data memory function is not used

ba5fnc 5pd

Display refresh rate

5if

bp5

Baud rate

Caution The balance may not transmit the data completely at the specified refresh rate,

depending on the baud rate or time, date and ID number appended to the weighing data.

Interval mode

The weighing data is periodically stored in memory.
Example

For

periodical

weighing without a personal computer command and to

output all of the data, to a computer, at one time.

Required

setting

dout

prt 3

Interval

mode

dout

data 2

Data memory function is used

dout

int

Interval

time