Chapter 1

4

Concord Express Installation Instructions

Shortcut
#

Function

Programmin
g page
reference

Default
setting

Required setting

0003

SIA False
Alarm
Reduction

34

On

On

0013

Exit
Extension

35

On

On

0014

Auto Stay
Arming

35

On

On

0016

Duress
Code

36

Disabled

Disabled

02005

Dialer Abort 43

On

On

02006

Dialer Abort
Delay

43

30 Sec.

15-45 sec.

02007

Cancel
Message

43

On

On

02009

Call Wait
Cancel

44

Disabled

On if reporting to central station and customer
has call waiting

0310

Entry Delay 46

30 sec.

30-240 sec.

0311

Exit Delay

47

60 sec.

45-184 sec.

05014

Swinger
Limit

52

1

1

0900

Smoke
Verify

61

Off

On if smoke alarms are programmed into
system

N/A

Cross
Zoning

88

Disabled

Enabled for zones with a high probability of
false alarms

The following table describes non-programmable (hard coded) system operation
as required to meet ANSI-SIA CP-01 and is provided only for your reference.

Function

Operation

Disarm During Entry Delay

Enter Code Only (or 1 + CODE)

Cancel Alarm

Enter Code Only (or 1 + CODE)

Abort Annunciation

Enabled

Cancel Report Annunciation

Enabled

UL 1635 Digital Alarm Communicator System

Note

: For UL 1635 installations, Entry Delay plus Dialer Abort Delay must not

exceed 60 seconds.