Special installation requirements, Ul listed systems – Interlogix Concord Express Installation Manual User Manual

Page 8

Advertising
background image

Chapter 1

2

Concord Express Installation Instructions

Special installation requirements

This security system can be used as a wire warning system, an intrusion alarm
system, an emergency notification system, or any combination of the three.

Some installations may require configurations dictated by city or state codes,
insurance, or Underwriter’s Laboratories (UL). This section describes the various
component and configuration listings.

UL Listed Systems

This section describes the requirements for UL Listed systems.

Basic System

• Control Panel (60-806, 60-806-95R)

• Backup Battery, 12 VDC, 4 AH (60-681)

• SuperBus 2000 2x16 LCD Touchpad (60-746-01), SuperBus 2000 Fixed

Display Touchpad (60-820), SuperBus 2000 2x20 LCD Touchpad (60-803), or
SuperBus 2000 2x20 VFD Touchpad (60-804)

• Standard Class II 16.5 VAC, 25 VA Power Transformer; manufacturer—Tech

Electro Ind, Inc. Part No. 48A0164 (60-822) or Standard Class II 16.5 VAC,
40 VA Power Transformer; MG Electronics Model # MGT1640CC, UTC Fire &
Security # 22-156

• 15-Watt, Dual Tone Siren (13-469) or Hardwire Siren (13-046)

Household Burglary Alarm System Unit (UL

1023)

Basic system, plus:

• Hardwire Magnetic Contact (Sentrol part # 1075-N or 1038T-N) or Wireless

Learn Mode Door/Window Sensor (60-362), Wireless Learn Mode PIR Motion
Sensor (60-703-95, 60-511, or 60-639)

• IMMEDIATE TROUBLE BEEPS set to on

• UL 98 OPTIONS set to on

• RECEIVER FAILURE set to on

• EXIT DELAY set to 60 seconds or less

• QUICK EXIT set to off

• SIREN TIMEOUT set to 4 minutes or more

• SIREN VERIFY set to on

• ENTRY DELAY set to 45 seconds or less