Chapter 1

Concord Express Installation Instructions

21

Connect 2x20 LCD/VFD touchpads to the panel power output and bus terminals
as shown in Figure 15 below.

Figure 15: Connecting 2x16 Alphanumeric Fixed Display LCD touchpad and 2x20
LCD/VFW touchpads

Installing an RJ-31X Phone Jack (13-081)

Note

: The panel cannot be used on a digital or PBX phone line. These systems

are designed only for digital type devices that operate anywhere from 5 volts DC
and up. The panel uses an analog modem and does not have a digital converter,
adapter, or interface to operate with such systems.

Use the following guidelines when installing an RJ-31X phone jack for system
control by phone and central station monitoring.

• Locate the RJ-31X jack (CA-38A in Canada) no further than five feet from the

panel.

• The panel must be connected to a standard analog (loop-start) phone line.

• For full line seizure, install an RJ-31X phone jack on the premises phone line

so the panel is ahead of all phones and other devices on the line. This allows
the panel to take control of the phone line when an alarm occurs even if the
phone is in use or off-hook.

• If an analog line is not available, contact your customers’ telecommunications

specialist and tell him/her you need an analog line off the phone switch (PBX
mainframe) or a 1FB (standard business line).