Chapter 1

Concord Express Installation Instructions

13

Installing Optional SnapCards

The SnapCard Header on the lower-left side of the panel accepts one of the
following SnapCard models:

• 8Z Input SnapCard—60-757
• 4 Output SnapCard—60-758
• 4Z Input/2 Output Combo SnapCard—60-756

Install the desired SnapCard onto the panel SnapCard Header and secure it in
place with two screws, included with the card (Figure 6 below).

Connect all necessary input/output wiring using the installation instructions
included with the SnapCard.

Figure 6: Installing a SnapCard

Installing Optional Hardwire Input Modules (HIMs)

Each SuperBus 2000 8-Zone Input Module (60-774) adds eight supervised
hardwire zones to the system. Both normally open and normally closed detectors
can be wired to module inputs (see Figure 8 on page 15).

Connect all necessary input/output wiring using the installation instructions
included with the HIM.

Note

: Use of the HIM with the Concord™ Express panel has not been

investigated by UL.