Concord Express Installation Instructions

31

Demo Kit Mode

System Programming
(Default = Off)

This setting determines whether the panel is used for a standard
installation (off) or as a demo kit (on). Turning on this feature and
performing a memory clear changes the following settings:

System Master Code = 1234

User Code 00 = 1001 (standard user code capabilities)

User Code 01 = 1002 (standard user code capabilities, bypass
sensors)

User Code 04 = 1122 (standard user code capabilities, system
tests)

Zone 1 (hardwire) = Group 10, Front Door

Zone 2 (hardwire) = Group 13, Bedroom Window

Zone 3 (hardwire) = Group 17, Living Room PIR

Zone 4 (hardwire) = Group 01, Panic

Zone 5 (wireless) = Group 01, Keychain Touchpad

Zone 6 (wireless) = Group 13, Kitchen Window

COMM FAILURE = off

Entry Delay = 8 seconds

Exit Delay = 8 seconds

Extended Delay = 1 minute

Siren Timeout = 2 minutes

Status Beeps = on (all touchpads)

Central Station Reporting = sensors learned into groups 01 and
03, Duress code use, and phone test (8 + CODE + 2)

To turn Demo Kit Mode
On or Off:

1. With the display

showing DEMO KIT
OFF/ON (current
setting), press 1 (off) or
2 (on). The display
flashes the entered
setting.

2. Press # and the display

shows DEMO KIT
OFF/ON (new setting).

3. Clear panel memory to

enable the demo kit
mode (see next menu).

Clear Memory (System Programming)

System Programming

Clearing memory with the Dealer Code deletes all
existing programming except the Dealer Code.

If the Dealer Code HAS NOT been set, clearing the
memory with the Installer Code deletes all existing
programming.

If the Dealer Code HAS been set, clearing the
memory with the Installer Code deletes all existing
programming except:

Dealer Code

Downloader Code

CS Phone 1

CS Phone 2

To clear Panel Memory:

1. With the system in program mode,

press B until the display shows
CLEAR MEMORY.

2. Press # and the display shows

ENTER CODE TO CLEAR
MEMORY.

3. Enter the 4-digit installer CODE (or

dealer if programmed) + #.

After about one second, the system
restarts and the panel scans the bus to
learn all bus devices. If the system
doesn’t respond as described, repeat
step 3.