Chapter 1

Concord Express Installation Instructions

3

• RF TX TIMEOUT set to 24 hours

• EXTENDED DELAY set to off

• TWO TRIP ERROR set to off

• ALARM VERIFY set to off

• DISABLE TROUBLE BEEPS set to off

• SYSTEM TAMPER set to on

Household Fire Warning System (UL 985)

Basic system plus:

• Hardwire Smoke Detector:

System Sensor models 2100D, 2100TD, 2100S, 2100TS, 2400, or 2400TH
learned into Sensor Group 26 Sentrol (ESL) models 429AT, 521B, or 521BXT
learned into sensor group 26

• Wireless Smoke Sensor 60-506-319.5 or 60-645-95 learned into sensor

group 26

• IMMEDIATE TROUBLE BEEPS set to on

• UL 98 OPTIONS set to on

• RECEIVER FAILURE set to on

• SIREN VERIFY set to on

• RF TX TIMEOUT set to 4 hours

• ALARM VERIFY set to off

• DISABLE TROUBLE BEEPS set to off

UL 1023 & 985 24-Hour Backup

For 24-hour backup, the total current draw for all connected devices is limited to
90 mA continuous using a 4.0 AH battery.

SIA System Requirements

Note

: UL requirements take priority over SIA requirements.

SIA system requirements are the same as those described for a UL Listed Basic
System on page 1, plus:

• If multiple annunciation is required, use Hardwire Siren part no.13-046.

SIA Setting Requirements

The following table describes programming requirements to meet ANSI-SIA CP-
01.