Chapter 2

46

Concord Express Installation Instructions

RF Tx Timeout (0301)

Timers-Global (Default=12 hours)

If any supervised wireless device stops sending
supervisory transmissions, the panel reports a
supervisory condition to the central station. This
setting determines how long the panel should wait
(2-24 hours) for a supervisory transmission before
sending the report.

Note

: For UL 985 & 1635 listed installations, the

RF Tx Timeout must be set to 4 hours. For UL
1023 listed installations, the RF Tx Timeout must
be set to 24 hours.

To set the RF Tx Timeout:

1. With the display showing RF TX

TIMEOUT nn HOURS (current setting),
enter the desired 2-digit timeout value
(02-24). The display flashes the entered
setting.

2. Press # and the display shows the new

setting.

Phone Test Freq. (0302)

Timers-Global (Default=7 days)

This setting determines how often the panel
sends the automatic phone test (see “Auto
Phone Test” under PHONE OPTIONS—
GLOBAL) to the central station (or a pager).
The phone test frequency can be set to report
every 1 to 255 days.

Note

: For UL 1635 listed installations, this

feature must be set to 1.

To set the Phone Test Freq:

1. With the display showing PHONE TEST

FREQ nnn DAYS (current setting), enter
the number of days (1-255). The display
flashes the entered setting.

2. Press # and the display shows the new

setting.

Next Phone Test (0303)

Timers-Global (Default=7 days)

This setting determines how many days (1-255)
until the next automatic phone test occurs.
When setting up Phone Test Freq, Next Phone
Test must be set to accurately count the
number of days left in the cycle before the next
phone test occurs. This setting should be the
same or less than the Phone Test Freq. setting.

Note

: For UL 1635 listed installations, this

feature must be set to 1.

To set the Next Phone Test:

1. With the display showing NEXT PHONE

TEST nnn DAYS (current setting), enter the
number of days (1-255). The display
flashes the entered setting.

2. Press # and the display shows the new

setting.

Output Trip Time (0304)

Timers-Global (Default=4 sec.)

This setting determines how long onboard
and SnapCard outputs are activated when
tripped (if they are configured for a
momentary response).

To set the Output Trip Time:

1. With the display showing OUTPUT TRIP TIME

nn SECONDS (current setting), enter the
number of seconds (1-12). The display flashes
the entered setting.

2. Press # and the display shows the new setting.