Interlogix Concord Express Installation Manual User Manual

Page 59

Advertising
background image

Chapter 2

Concord Express Installation Instructions

53

Swinger Limit (05014)

Reporting-Global (Default=1)

This setting determines the maximum number of
times a sensor or zone can go into alarm (during
a single arming period) before the panel
automatically bypasses that sensor or zone. This
feature only applies to sensors in groups 00-20,
29, or 34.

When set to 1, the panel automatically bypasses
a sensor or zone after it causes an alarm. When
set to 2, the panel waits until a sensor or zone
has caused a second alarm (during the same
arming period) before bypassing it. At either
setting, the automatic bypass is logged into the
event buffer.

A bypassed zone or sensor will be cleared
(automatically “unbypassed”) if the system
receives no further activations from that sensor
or zone over the next 48-50 hours.

Changing the arming level also clears all
automatically bypassed sensors and zones and
resets the Swinger Limit count on all sensors and
zones.

To set the Swinger Limit:

1. With the display showing SWINGER LIMIT

n (current setting), press 1 or 2. The display
flashes the entered setting.

2. Press # and the display shows the new

setting.

The following describes how to program the settings that appear under
REPORTING—PARTITION 1.

Opening Reports (0510)

Reporting-Partition 1 (Default=off)

This setting determines whether or not
the panel sends an opening report to the
central station (or pager) after disarming
the system.

Note

: To use this feature, the

Open/Close Reports settings under the
PHONES—CS PHONE 1-2 and/or
PHONES—PAGER PHONE 1-3 menus
must be turned on for the specific CS
Phone or Pager Phone number.

To turn Opening Reports off or on:

1. With the display showing OPENING REPORTS

OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.

2. Press # and the display shows the new setting.

Advertising