Interlogix Concord Express Installation Manual User Manual

Page 28

Advertising
background image

Chapter 1

22

Concord Express Installation Instructions

To connect a phone line to the panel using an RJ-31X/CA-38A jack:

1. Run a 4-conductor cable from the TELCO protector block to the jack location

(see A in Figure 16 below).

2. Connect one end of the cable to the jack (see B in Figure 16 below).

Figure 16: Installing an RJ-31X Phone Jack

3. At the TELCO protector block, remove the premises phone lines (lines from

phone jacks on premises) from the block and splice them to the black and
white (or yellow) wires of the
4-conductor cable (see C in Figure 16 above).

Note

: Connecting the panel to an analog line off the phone switch places the

panel ahead of the phone system which prevents panel access from phones
on the premises. However, the panel can still be accessed from off-site
phones.

4. Connect the green and red wires from the 4-conductor cable to the TIP (+)

and RING (-) posts on the block (see D in Figure 16 above).

5. Check the phones on the premises for dial tone and the ability to dial out and

make phone calls. If phones do not work correctly, check all wiring and make
corrections where necessary. Proceed to the “Troubleshooting” section of this
manual if problems persist.

Connecting the Phone Line to the Panel with a DB-8
Cord

After installing the RJ-31X jack, you are ready to connect the phone line to the
panel. A DB-8 cord (not included) uses a plug at one end for connecting to the
RJ-31X module and flying leads on the other end for panel terminal connections.

Advertising