Chapter 2

50

Concord Express Installation Instructions

Buffer Control (05001)

Reporting-Global (Default=off)

When this setting is on, only arming level
changes are logged into the buffer
(memory) of the panel. When this setting
is off, all system events are logged in the
buffer.

To turn Buffer Control off or on:

1. With the display showing BUFFER CONTROL

OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.

2. Press # and the display shows the new setting.

Back In Service (05002)

Reporting-Global (Default=on)

When this feature is turned on, the panel
reports to the central station when AC
and backup battery power are restored
(after an extended power outage).

To turn Back In Service reports off or on:

1. With the display showing BACK IN SERVICE

OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.

2. Press # and the display shows the new setting.

Bypass Reports (05003)

Reporting-Global (Default=off)

When this feature is turned on, the panel
reports to the central station (or a pager)
whenever sensors or zones are
bypassed.

To turn Bypass Reports off or on:

1. With the display showing

BYPASS REPORTS

OFF/ON

(current setting), press 1 (off) or 2 (on).

The display flashes the entered setting.

2. Press # and the display shows the new setting.

Low CPU Battery (05004)

Reporting-Global (Default=on)

When this setting is on, the panel reports
a low panel battery to the central station
(or pager) before shutting down.

Note

: For UL listed systems, Low CPU

Battery must be set to “on.”

To turn Low CPU Battery reports off or on:

1. With the display showing LOW CPU BATTERY

OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.

2. Press # and the display shows the new setting.

Battery Restoral (05005)

Reporting-Global (Default=off)

If this setting is on, the panel reports to
the central monitoring station (or pager)
when the panel battery is restored or
replaced or when a wireless sensor
reports a battery replacement to the
panel.

To turn Battery Restoral reports off or on:

1. With the display showing BATTERY RESTORAL

OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.

2. Press # and the display shows the new setting.