ANCE

AutoSteer Setup

Icon

Description

Factory Setting Range

User Setting

Autosteer

On

Valve Type

Standard PWM

Valve Frequency

175 Hz

0.9 - 15000.1 Hz

Minimum Duty Cycle Left

20.0%

0.0 - 50.0%

Minimum Duty Cycle Right

20.0%

0.0 - 50.0%

Maximum Duty Cycle

50%

25 - 100%

Coarse Steering Adjustment

25.0

1.0-100.0

Fine Steering Adjustment

25.0

1.0-100.0

Deadband

1

1-10

Lookahead

4.0

0.0-10.0

Steering Wheel Sensor

Magnetic

Angle Sensor

Disabled

Tilt Gyro Module Setup

Icon

Description

Factory Setting Range

User Setting

Tilt Correction On/Off

Off

Video Setup

Icon

Description

Factory Setting Range

User Setting

A

B

Cameras

Normal

data management

Options

Icon

Description

Factory Setting Range

User Setting

Job Mode

Varies depending on release version.