|  VISIX  PTZ  Network  Camera  

 

 

10225  Westmoor  Drive,  Suite  300,  Westminster,  CO  80021  |  www.3xlogic.com  |  (877)  3XLOGIC

 

 

82  

The  RS-­‐485  serial  port  is  used  to  control  the  PTZ  of  the  camera.  The  configuring  of  the  PTZ  parameters  
should  be  done  before  you  control  the  PTZ  unit.  
Steps:  
1) Enter  RS-­‐485  Port  Setting  interface:  
Configuration>  Advanced  Configuration>  System  >  RS485    

 

Figure  10-­‐15

RS-­‐485  Settings  

2) Set  the  RS-­‐485  parameters  and  click  

  to  save  the  settings.  

By  default,  the  Baud  Rate  is  set  as  9600  bps,  the  Data  Bit  is  8,  the  stop  bit  is  1  and  the  Parity  and  
Flow  Control  is  None.  

NOTE:

 The  Baud  Rate,  PTZ  Protocol  and  PTZ  Address  parameters  of  the  speed  dome  should  be  

exactly  the  same  as  those  of  the  remote  control  device.  

 
 

 