9 home return mode, Home return mode – ADLINK PCI-8102 User Manual

Page 151

Advertising
background image

140

Function Library

SVacc: Specified velocity interval in which S-curve acceleration is
performed.

Note: SVacc = 0, for pure S-Curve. For more details, see

section 4.2.4

SVdec: specified velocity interval in which S-curve deceleration is
performed.

Note: SVdec = 0, for pure S-Curve. For more details, see

section 4.2.4

6.9

Home Return Mode

@ Name

_8102_set_home_config – Set the configuration for

home return.

_8102_home_move – Perform a home return move.

_8102_home_search – Perform auto home search

@ Description

_8102_set_home_config:

Configures the home return mode, origin & index signal(EZ) logic,
EZ count, and ERC output options for the home_move() function.
Refer to Section 4.1.8 for the setting of home_mode control.

_8102_home_move:

This function will cause the axis to perform a home return move
according to the _8102_set_home_config() function settings. The
direction of movement is determined by the sign of velocity param-
eter (svel, mvel). Since the stopping condition of this function is
determined by the home_mode setting, users should take care in
selecting the initial moving direction. Users should also take care
to handle conditions when the limit switch is touched or other con-
ditions that are possible causing the axis to stop. Executing
v_stop() function during home_move() can also cause the axis to
stop.

_8102_home_search:

Advertising