4 origin signal org, Origin signal org – ADLINK PCI-8102 User Manual

Page 37

Advertising
background image

26

Signal Connections

3.4

Origin Signal ORG

The origin signals (ORG0~ORG1) are used as input signals for the
origin of the mechanism. The following table lists signal names,
pin numbers, and axis numbers:

The input circuit of the ORG signals is shown below. Usually, a
limit switch is used to indicate the origin on one axis. The specifi-
cations of the limit switch should have contact capacity of +24V @
6mA minimum. An internal filter circuit is used to filter out any high
frequency spikes, which may cause errors in the operation.

When the motion controller is operated in the home return mode,
the ORG signal is used to inhibit the control output signals (OUT
and DIR). For detailed operations of the ORG signal, refer to sec-
tion 4.3.

P1 Pin No

Signal Name

Axis #

24

ORG0

1

58

ORG1

2

Inside 8102

P1