6.10 Manual Pulser Motion

@ Name

_8102_disable_pulser_input – Disable the pulser

input

_8102_pulser_pmove – Manual pulser p_move

_8102_pulser_vmove – Manual pulser v_move

_8102_set_pulser_ratio – Set manual pulser ratio

for actual output pulse rate

_8102_set_pulser_iptmode – Set the input signal

modes of pulser

@ Description

_8102_disable_pulser_input

This function is used to set the pulser input disabel or enabel.

_8102_pulser_pmove

With this command, the axis begins to move according to the man-
ual pulse input. The axis will output one pulse when it receives one
manual pulse, until the _8102_disable_pulser_input function dis-
ables the pulser or the output pulse number reaches the distance.

_8102_pulser_vmove

With this command, the axis begins to move according to the man-
ual pulse input. The axis will output one pulse when it receives one
manual pulse, until the _8102_disable_pulser_input function dis-
ables the pulser.

_8102_set_pulser_ratio

Set manual pulse ratio for actual output pulse rate. The formula for
manual pulse output rate is:

Output Pulse Count = Input Pulser Count × 4 (MultiF +1) ×(DivF
+1) / 2048

The DivF = 0~2047 Divide Factor

The MultiF= 0~31 Multiplication Factor

_8102_set_pulser_iptmode

This function is used to configure the input mode of manual pulser.