15 position compare and latch – ADLINK PCI-8102 User Manual

Page 173

Advertising
background image

162

Function Library

CntValue, * CntValue: the counter value

T_pos, *T_pos: Target position recorder value,

range: -134217728~134217727

Res_Distance, * Res_Distance: residue distance

6.15 Position Compare and Latch

@ Name

_8102_set_trigger_logic – Set the CMP signal’s

logic

_8102_set_trigger_comparator – Set the trigger

comparator

_8102_set_error_comparator – Set the error

comparator

_8102_set_general_comparator – Set the general

comparator

_8102_set_latch_source – Set the latch timing for

a counter

_8102_set_ltc_logic – Set the logic of LTC signal

_8102_get_latch_data – Get the latch datas from

counter

@ Description

_8102_set_trigger_logic:

This function is used to set the logic of CMP single.

_8102_set_error_comparator:

This function is used to set the comparison method and value for
the error comparator. When the position error counter’s value
reaches the comparing value, the 8102 will generate an interrupt
to the host PC. Also see section 6.14 “Interrupt control”.

_8102_set_general_comparator: