2 motor connection, 3 filters, 6wiring – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 117: 5 emc-compliant wiring

Advertising
background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-13

6.5

EMC-compliant wiring

6

Wiring

6.5.2.2

Motor connection

Motor connection

6-

][Verdr_Motorstecker

The cable shield for the motor cable is connected to the servo amplifier

housing via the shielding plate.

Use the ready-made motor cable from Pilz (accessory). However, if you

wish to wire your own motor connector, follow the instructions below:

6.5.3

Filters

Filters

6-

][EMV_Filter

Noise suppression filters are integrated within the servo amplifier for the

mains voltage and 24 V supply voltage.

These noise suppression filters are used to:

`

Protect the devices from conducted, high frequency disturbances

(noise immunity)

`

Reduce a device's high frequency disturbances. These disturbances

are emitted via the the mains cable or via emissions from the mains

cable. The noise suppression filters limit the noise emissions to a

specified amount.

Strip the outer cable sheath to ap-
prox. 20-25 mm in length, without
damaging the braided shield
.

Push the braided shield back over the
cable.

Shorten all the wires except for the
protective earth PE (green/yellow) by
approx. 20 mm. The PE wire is now
the longest.

Strip all the wires and fit end ferrules.

Wire the connector as shown in the
connection diagram.

Hook the shielded connection termi-
nal on to the shielding plate. Screw
the shielded connection terminal into
place. This provides ample, conduc-
tive contact between the braided
shield and the front plate.

Plug the connector into the slot on the
front of the servo amplifier.

Advertising
This manual is related to the following products:

PMCprimo DriveP.01/AA0/5/0/0/208-480VAC, PMCprimo DriveP.12/AA0/4/0/0/208-480VAC, PMCprimo DriveP.12/AA0/4/P/0/208-480VAC, PMCprimo DriveP.03/AA0/4/0/0/208-480VAC, PMCprimo DriveP.06/AA0/4/0/0/208-480VAC, PMCprimo DriveP.24/ABB/4/0/0/208-480VAC, PMCprimo DriveP.03/AB0/5/0/0/208-480VAC, PMCprimo DriveP.06/AB0/2/0/0/208-480VAC, PMCprimo DriveP.03/AB0/3/0/0/208-480VAC, PMCprimo DriveP.06/AB0/3/0/0/208-480VAC, PMCprimo DriveP.12/AB0/2/0/0/208-480VAC, PMCprimo DriveP.12/ABC/4/P/0/208-480VAC, PMCprimo DriveP.12/AB0/3/0/0/208-480VAC, PMCprimo DriveP.03/AB0/2/0/0/208-480VAC, PMCprimo DriveP.12/AAC/4/0/0/208-480VAC, PMCprimo DriveP.24/AA0/5/0/0/208-480VAC, PMCprimo DriveP.12/AA0/2/0/0/208-480VAC, PMCprotego D.01/000/0/0/2/208-480VAC, PMCprotego D.03/000/0/0/2/208-480VAC, PMCprotego D.06/000/0/0/2/208-480VAC, PMCprotego D.12/000/0/0/2/208-480VAC, PMCprotego D.24/000/0/0/2/208-480VAC, PMCprotego D.12/000/0/P/2/208-480VAC, PMCprotego D.24/000/0/P/2/208-480VAC, PMCprotego D.01/200/0/0/2/208-480VAC, PMCprotego D.01/100/0/0/2/208-480VAC, PMCprotego D.01/010/0/0/2/208-480VAC, PMCprotego D.06/010/0/0/2/208-480VAC, PMCprotego D.06/100/0/0/2/208-480VAC, PMCprotego D.06/200/0/0/2/208-480VAC, PMCprotego D.03/010/0/0/2/208-480VAC, PMCprotego D.03/200/0/0/2/208-480VAC, PMCprotego D.03/100/0/0/2/208-480VAC, PMCprotego D.12/010/0/0/2/208-480VAC, PMCprotego D.24/200/0/P/2/208-480VAC, PMCprotego D.12/200/0/0/2/208-480VAC, PMCprotego D.12/100/0/0/2/208-480VAC, PMCprotego D.12/010/0/P/2/208-480VAC, PMCprotego D.12/200/0/P/2/208-480VAC, PMCprotego D.24/100/0/P/2/208-480VAC, PMCprotego D.24/010/0/P/2/208-480VAC, PMCprotego D.12/100/0/P/2/208-480VAC, PMCprotego D.24/200/0/0/2/208-480VAC, PMCprotego D.24/100/0/0/2/208-480VAC, PMCprotego D.24/010/0/0/2/208-480VAC