6.7

Control element

6

Wiring

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-54

The CANopen specification CiA DS-301 V4.0 requires the cable at both

the start and end of the bus to be terminated with a resistor (120 Ohm,

5% metal film, 1/4 Watt).

The terminating resistor is usually integrated within the connector and

can be activated there.

The cable runs for reliable communication decrease as the transmission

rate is increased. The following values can be used as a guide, but they

should not be regarded as limit values:

Cable data:

`

Characteristic impedance 100 - 120

Ω

`

Operating capacitance max. 60 nF/km

`

Cable resistance (loop) 159.8

Ω

/km

Cable runs in relation to transmission rate

Longer cable runs can be achieved with lower cable capacitance (max.

30 nF/km) and lower conductor resistance (loop, 115

Ω

/km).

Characteristic impedance 150 ± 5

Ω

=> terminating resistor 150 ± 5

Ω

.

For EMC reasons, the D-Sub connector housing must meet the follow-

ing requirements:

`

Metal or metal coated

Connection

Interface

CANopen

Shielded cable

The interface is on the same connec-
tor as the RS 232 interface.

The RS 232 and CANopen interface
use the same operating earth (GND).

Cable runs in relation to transmission rate

Transmission rate [kBit/s]

Max. cable runs [m]

1000

10

500

70

250

115

CAN_H

9

6

PMCprotego

X6

CAN_L

CANopen Server/Client

5

CAN_GND

CAN_H

CAN_L

CAN_GND

Advertising
This manual is related to the following products:

PMCprimo DriveP.01/AA0/5/0/0/208-480VAC, PMCprimo DriveP.12/AA0/4/0/0/208-480VAC, PMCprimo DriveP.12/AA0/4/P/0/208-480VAC, PMCprimo DriveP.03/AA0/4/0/0/208-480VAC, PMCprimo DriveP.06/AA0/4/0/0/208-480VAC, PMCprimo DriveP.24/ABB/4/0/0/208-480VAC, PMCprimo DriveP.03/AB0/5/0/0/208-480VAC, PMCprimo DriveP.06/AB0/2/0/0/208-480VAC, PMCprimo DriveP.03/AB0/3/0/0/208-480VAC, PMCprimo DriveP.06/AB0/3/0/0/208-480VAC, PMCprimo DriveP.12/AB0/2/0/0/208-480VAC, PMCprimo DriveP.12/ABC/4/P/0/208-480VAC, PMCprimo DriveP.12/AB0/3/0/0/208-480VAC, PMCprimo DriveP.03/AB0/2/0/0/208-480VAC, PMCprimo DriveP.12/AAC/4/0/0/208-480VAC, PMCprimo DriveP.24/AA0/5/0/0/208-480VAC, PMCprimo DriveP.12/AA0/2/0/0/208-480VAC, PMCprotego D.01/000/0/0/2/208-480VAC, PMCprotego D.03/000/0/0/2/208-480VAC, PMCprotego D.06/000/0/0/2/208-480VAC, PMCprotego D.12/000/0/0/2/208-480VAC, PMCprotego D.24/000/0/0/2/208-480VAC, PMCprotego D.12/000/0/P/2/208-480VAC, PMCprotego D.24/000/0/P/2/208-480VAC, PMCprotego D.01/200/0/0/2/208-480VAC, PMCprotego D.01/100/0/0/2/208-480VAC, PMCprotego D.01/010/0/0/2/208-480VAC, PMCprotego D.06/010/0/0/2/208-480VAC, PMCprotego D.06/100/0/0/2/208-480VAC, PMCprotego D.06/200/0/0/2/208-480VAC, PMCprotego D.03/010/0/0/2/208-480VAC, PMCprotego D.03/200/0/0/2/208-480VAC, PMCprotego D.03/100/0/0/2/208-480VAC, PMCprotego D.12/010/0/0/2/208-480VAC, PMCprotego D.24/200/0/P/2/208-480VAC, PMCprotego D.12/200/0/0/2/208-480VAC, PMCprotego D.12/100/0/0/2/208-480VAC, PMCprotego D.12/010/0/P/2/208-480VAC, PMCprotego D.12/200/0/P/2/208-480VAC, PMCprotego D.24/100/0/P/2/208-480VAC, PMCprotego D.24/010/0/P/2/208-480VAC, PMCprotego D.12/100/0/P/2/208-480VAC, PMCprotego D.24/200/0/0/2/208-480VAC, PMCprotego D.24/100/0/0/2/208-480VAC, PMCprotego D.24/010/0/0/2/208-480VAC