1 point source spl mapping – d&b TI 385 d&b Line array design User Manual

Page 31

Advertising
background image

Attenuation balloon
The diagram displays the 3D polar plot of the selected

loudspeaker in the form of an attenuation balloon or

alternatively the projection of the listening planes in the

horizontal direction of the main axis, the main axis itself and

the nominal –6 dB axes.

— Dragging with the mouse alters the viewing angle.
— Turning the mouse wheel zooms in and out.
— Double-clicking into the diagram always takes you back

to the default side view.

10.9.1 Point source SPL mapping

Point source SPL mapping

The mapping plot shows

the calculated level distribution on

all active listening planes including the level contribution of

all sources of the currently active point source group, the

positions of the cabinets, their aiming and their nominal

– 6 dB coverage.

Spatial resolution of the SPL mapping
The spatial resolution of the mapping calculation is fixed to

1m with a minimum of 400 points per plane.

Signal selection and SPL summation method

You can select the simulated frequency range in standard

third octave bands.

For frequency bands of 163 Hz and below you can use

complex SPL summation as an option thus showing

interferences. Higher frequencies are always displayed as

an energy sum. To display interferences correctly and

totally, the spatial resolution of the mapping has to be in the

range of half the wavelength of the simulated frequency.

The 163 Hz band is able to fulfill this requirement for a

minimum resolution of 1 m. A mapping with a higher

resolution would dramatically increase calculation time

while providing minimum additional information.
Here you can also set the signal level that is applied to all

amplifier inputs. The selected frequency band is monitored

for sufficient headroom (Refer to section 10.7.9 Maximum

SPL and headroom on page 27).

Air absorption
When the Air Absorption switch is activated, ArrayCalc

calculates this effect for selectable temperature and

humidity values. The Air Absorption switch and the
environmental settings are located in the Extras-Options
menu and are also directly available from the toolbar. T

o

define the temperature units, click Extras-Options and

choose between degrees Celsius and Fahrenheit under

Units. The relative humidity can be specified in 4 steps:

"dry-20 %" , "low-40 %", "std-60 %" and "high-80 %".
The global Air absorption switch and the environmental

settings affect all SPL calculations both on the Sources page

as well as on the 3D plot page (refer to section 10.7.10 Air

absorption on page 27).

Color scale

The color scale for the SPL mapping has a fixed

6 dB per division resolution. The color scale

window displayed can be set according to the

calculation results. This is done by either clicking the

+/-- buttons underneath the scale or using the

mouse wheel while the mouse pointer is on the

scale. The small arrow to the right of the scale

indicates the highest SPL value calculated for the

plot.
The color scale does not rescale automatically. This

enables you to quickly notice the result of any

change in the setup while optimizing the project.

For a start, we recommend you to set the scale

taking the displayed "highest SPL" value as a

reference.

Automatic calculation and status

When the Autocalculate switch is

activated, the 3D mapping

calculation immediately starts as

soon as any relevant parameter

in the project is changed.
The calculation starts using a very

rough resolution, getting more and more detailed until the

maximum resolution is reached. In this process the mapping

plot is constantly updated.

TI 385 (6.0 EN) d&b Line array design, ArrayCalc V8.x

Page 31 of 54

Advertising