d&b TI 385 d&b Line array design User Manual

Page 41

Advertising
background image

A mapping with a higher resolution would dramatically

increase calculation time while providing minimum

additional information.
Here you can also set the signal level that is applied to all

amplifier inputs. The selected frequency band is monitored

for sufficient headroom (Refer to section 10.7.9 Maximum

SPL and headroom on page 27).

Air absorption
Use the Air absorption switch to consider air absorption in

the SPL calculations. The Air absorption switch is located in

the Extras-Options menu and directly accessible from the

toolbar. The related settings for temperature and relative

humidity are also accessible there. (Refer to section

10.7.10 Air absorption on page 27).

Color scale

The color scale for the SPL mapping has a fixed

6 dB per division resolution. The color scale

window displayed can be set according to the

calculation results. This is done by either clicking the

+/-- buttons underneath the scale or using the

mouse wheel while the mouse pointer is on the

scale. The small arrow to the right of the scale

indicates the highest SPL value calculated for the

plot.
The color scale does not rescale automatically. This

enables you to quickly notice the result of any

change in the setup while optimizing the project.

For a start, we recommend you to set the scale

taking the displayed "highest SPL" value as a

reference.

Automatic calculation and status

When the "Autocalculate" switch is

activated, the 3D mapping

calculation immediately starts as

soon as any relevant parameter in the project is changed,

even if the 3D plot tab is currently not active.
The calculation starts using a very rough resolution, getting

more and more detailed until the resolution set in the

options is reached. In the process, the 3D plot is constantly

updated.
This procedure allows you to modify setup parameters as

soon as a certain result or behavior is perceptible without

having to wait for the calculation to be completed. The

progress of the calculation in relation to the target resolution

is displayed in per cent.

Note: However, please note that constant

recalculation will lead to a persistently high processor

load and will quickly discharge your notebook batteries.

For this reason, when working on notebook computers

without AC supply, switch off the "Autocalculate"

function. You can trigger a recalculation manually by

clicking the "Recalculate" button. If a relevant parameter

in the project has been modified since the last

calculation, this is indicated by "Recalculate (required)".

Memories and display options
The 3D plot provides three memories to store calculated

mapping results and various display options. This feature

enables you to compare either different frequency bands

for one source configuration or different source

configurations for the entire venue.
In the "Memories" section underneath the diagram you can

store a calculated mapping result with the current viewport

settings including all related project data such as room and

array configurations to a particular memory (A, B or C) by

clicking one of the Save buttons. If you want to edit the

data of a memory, click the respective "Load" button next to

the "Save" button.
This will load the stored mapping results including the

complete room and source configurations to the live

workspace. Please note that loading a stored memory will

overwrite the current settings of your live workspace.

You can view a memory by selecting the

respective display option on the left side of

the diagram. You can choose individual

views (Live, A, B or C) or a combined view of

all results (Quad). If you want to change the

default preset view for a memory, display the

respective memory A, B or C individually and

select the desired preset view. This view will

then also be displayed in the Quad view.

Keep in mind that this option is intended for display

purposes only. The related project settings are not loaded

to your live workspace.

Notes:
1. ArrayCalc does not store any mapping results when

you save a project file. Only the project, room and

array settings of the live workspace are saved. Also

the A, B and C memories are only temporarily

stored during an ArrayCalc session. As soon as you

exit ArrayCalc, this data is also lost. That means, if

you want to keep the project configuration on which

an SPL mapping is based and which you stored to

one of the memories, you have to load the relevant

memory to the live workspace and then save it as a

project. When the project configuration has been

saved, the mapping results can easily be

recalculated by loading and recalculating the

respective project file.

2. Saving and loading high-resolution mapping data

for large venues can take a lot of time and require

massive amounts of RAM, easily reaching the

gigabyte range!

Print and Export
You can print out all possible display options of the

mapping diagram(s) or you can export them in *.png

format for further use in documentation. To use the print or

export function, select "Print" or ''Export" from the File menu.

TI 385 (6.0 EN) d&b Line array design, ArrayCalc V8.x

Page 41 of 54