d&b TI 385 d&b Line array design User Manual

Page 40

Advertising
background image

Aligning a L/R subwoofer setup
The delay alignment tool can also be used to align L/R

ground stacked subwoofers to any other source. Set the

number of subwoofer sources to 1. Now only the center

source is active. Enter the x and y coordinates of the left

ground stack and proceed as before.

10.12 3D plot page
ArrayCalc offers the possibility to calculate an SPL mapping

including all sources in the project on all defined listening

planes for a selectable third octave frequency band.

ArrayCalc, 3D plot

The left side of the page contains a fully operable copy of

the project, room and source settings of the project.
The calculation results are displayed in a zoomable, mouse

controlled 3D diagram that is fully rotatable.

Preset views

Directly underneath the diagram area, you can choose

between different standard views: "Top" - view from above

onto the x-y plane, "End" - view from the end onto the y-z

plane, "Side" - view from the house left side onto the x-z

plane and a standard 30°/30° "Isometric" view. The

preset views always affect the diagram situated directly

above them.
In addition, you can define any other view by clicking and

holding down the left mouse button in the diagram when

moving the mouse. An up/down movement rotates the

viewport around the x-axis, a left/right movement rotates it

around the y-axis.
Holding down the right mouse button while moving

left/right rotates the viewport around the z-axis. The

distance between the click position and the rotational axis

defines the leverage of the movement.
Turning the mouse wheel zooms in and out.

You can also move the diagram by holding down the CTRL

key (Apple key for Macintosh) while clicking in the diagram

and holding down the left mouse button when moving the

mouse.
If you are completely lost, simply click one of the preset

views or double-click into the diagram. This will restore the

last preset view selected.

Show sources / show source dispersion
When the Show sources switch is enabled, 3D rendered

drawings of all sources are displayed. As usual, the

selected source is highlighted.
When the Show source dispersion switch is enabled, the

main axis of the first TOP cabinet of each array as well as

the nominal dispersion axes of the first and the last TOP

cabinets of each array are displayed in the diagram. For

point sources, the main axis of each cabinet is displayed.

Spatial resolution of the SPL mapping

Mapping resolution

The spatial resolution of the mapping calculation in the 3D

plot can be selected underneath the diagram. Possible

settings are High (1 m) / Mid (2 m) / Low (5 m). Between

each of them, the time for a full calculation increases by a

factor of 4. A resolution of 2 m is used as default setting.
Be aware that high resolution mapping calculations of large

venues (arena or stadium) using many large arrays can

easily exceed 15 minutes of calculation time and will

require a lot of RAM memory!
For detailed calculations of particular areas only the

relevant listening planes may be switched on in the Room

settings menu. This improves calculation time and ensures a

maximum sized display of the planes.

Signal selection and SPL summation method

You can select the simulated frequency range in standard

third octave bands.
For frequency bands of 163 Hz and below you can use

complex SPL summation as an option thus showing

interferences. (SPL calculation within each array is always

based on complex summation). Higher frequencies are

always displayed as an energy sum.
To display interferences correctly and totally, the spatial

resolution of the mapping has to be in the range of half the

wavelength of the simulated frequency. The 163 Hz band is

able to fulfill this requirement for a minimum resolution of

1 m.

TI 385 (6.0 EN) d&b Line array design, ArrayCalc V8.x

Page 40 of 54